Working Process:
Raw Water→Raw water pump→Mechanical filters→Activated carbon filter→Add antiscalant→Precision filters→RO high pressure pump→RO reverse osmosis membrane element→Finished water
1. Water tank: storage of tap water, to solve the problem ofinsufficient tap water pressure and the back booster pump due to the impact of insufficient water, reduce the failure rate.
2.Booster pump: equipped with a stainless steel pump, to provide sufficient pressure for subsequent filtration.
3. Quartz sandfilter: mainly remove the mud, suspended solids and large particles in the tap water.
4. Carbon filter: mainly remove organic substances, residual chlorine and odor in tap water.
5.Security filter: further filtration, protection of reverse osmosis membrane.
6.High pressure pump: provide enough pressure for reverse osmosis system.
7. Reverse osmosis unit: the core part of pure water equipment, the production of high-purity water.
8.Pure water tank: storage pure water, can change the size of the water tank,after the below process,The water result is pure enough for different application.
You can choose FRP or stainless steel tank filter system and with or without pre-filter.We can customize the system according to your requirements.
Parameters | HYHJ-RO-6T | ||
Machine Size(L*W*H) | 5500mm*900mm*1850mm (Can be designed according to the site) | ||
Equipment treatment process | Raw water→raw water pump→mechanical filter → activated carbon filter→add scale inhibitor→Precision filter→RO high-pressure pump→ROreverse osmosis membrane element→finished water | ||
Control mode | Fully automatic operation | Device power | AC/380V/50HZ |
Unladen weight | 2000KG | Running weight | 4000KG |
Raw water pump | Q=12m³/H H=30m | High pressure pumps | Q=12m³/H H=110m |
Quartz sand filter | φ950×1900mm | Activated carbon filter | φ950×1900mm |
Precision filters | 7 core 40 inches | Precision filter element | 40''5μm |
Scale inhibitor dosing pump | Q=1L/H H=50m | Scale inhibitor dosing box | 40L |
Reverse osmosis membrane vessels | 1 core 8 inches | Reverse osmosis membrane model | 8040 |